18/08/2006 to 23/08/2006 temperature and humidity, main sensor was replaced due to a fault,
{solar sensor,barometer,1 soil sensors rain gauge working okay}
23/08/2006 Time 11.00am temperature and humidity, main sensor replaced and reactivated
1/11/2006
Modified rain gauge heater installed a thermal cut-out switch operating temperature
{ open at 30c off } { and reset 20c on }
Made and installed a insulating jacket to the outside the rain gauge
10/11/2006 Moved the weather station data software to a dedicated PC
17/11/2006 Installed a 1000vA UPSmart power backup system on the computer, Full surge protection, overload protection, CPU controlled
17/11/2006 installed a 500vA Back UPS for Weather station console ,Full surge protection, overload protection
20/11/2006 Added a UV filter to the Webcam lens , this will help with the glare from the window and direct sun into the lens
{old UV filter of a 35 millimetre lens}
21/11/2006 Solar sensor, Added a black tube which clips on to the probe this was made from a car in line, fuse holder
one end of the tube covers the probe, the tube extends and touches the glass globe, the tube is open ended
this has definitely improved the sensitivity
Before installing the black tube I had to lower the settings in the solar sensor setup {Winter settings} I wanted to keep all the settings the same through the year,
since adding the tube I have gone back to the summer settings, overcoming the need for a winter setting
Added Thermo Sensor on a Concrete Slab 12" x 12"
02/12/06 Added 3 Wireless 433mhz Repeater to extends the reception distance on some of the sensors
30/11/2006
Internet provider stopped trading
there was no earlier warning before cutting off the Internet connection
Reapplying Internet connection with talk talk they promised to get reconnected soon as possible
go live date is 28/1/2007
21/1/2007
Fixed the Traditional gauges in the Stevenson screen I have altered the screen to take the Sheathed ordinary Hygrometer .
Met Office pattern (BS692). + a small fan to help with air flow
25/01/2007
Added a sensor for UV INDEX Oregon Scientific UVR 138 (Ultra-Violet)
data is read manually
25/01/2007
Added a device for measuring a uv dose at 30 minutes in the sun
the reading is m J/cm 2 data is read manually
21/02/2007
subscribe to StrikeStar for Live lightning Data
07/03/2007
1 wire weather station to add extra sensors
Added a Lightning sensor
28/03/2007
Made bracket and assembled the wet leaf sensor
should be operational sometime in May
06/04/2007
Made stainless steel electrodes for the soil monitoring
and cast Gypsum Block around electrodes
23/04/2007
Assembling, Replacing main mounting pole ,
aluminium and stainless steel mounting brackets for sensors
26/04/2007
added Wet Leaf sensor
07/05/2007
Soil moisture Now working
07/06/2007
Added a Surge protector
circuit boards made in-house
06/07/2007
Remounted moisture sensors, to a plastic backing plate
Rewired and replaced water proof box with cable glands
23/08/2007
Replaced soil sensor
Installed watermark soil sensor and calibrated
At a depth of 5 inches
200 dry- 0 wet
27/08/2007
Installed 1 wire soil temperature probe
at a depth of 5 inches
Checked all temperature sensors and calibrated
Added a control box to the rain gauge heater
+ 1 wire temperature probe
1/10/2007
Checked the rain gauge calibration settings, everything is fine, no alterations made
03/ 11/ 2007
Added a rain duration sensor { data is being displayed as wet leaf Sensor untell whether display can accommodate this as a separate sensor)
02/02/2008
Added a ultraviolet sensor ( interfaced with a Oregon extra temperature sensor wireless)
Added a rain duration sensor ( interfaced with a Oregon extra temperature sensor wireless)
04/03/2008
Added a adjustable stand for the rain duration sensor
08/03/2008
Added a adjustable stand for the UV sensor
13/03/2008
Redesigned rain gauge heater using a 20w halogen light
19/03/2008
Serviced the rain sensor, And added a adjustable stand this will give optimum levelling options
10/04/2008
Installed prototype Oregon wireless solar radiation sensor calibration will take a few days
32/04/2008
Cleaned homemade Solar Radiation screen ,checked calibration of temperature and humidity-wet bulb
compared the readings with the traditional Sheathed ordinary Hygrometer Met Office pattern (BS692)
temperature readings spot-on / humidity readings were reading lower and this is due to the nature
of electronic humidity Sensor calibrating is necessary once a year readings are now spot-on
03/10/2008
I have now replaced the Oregon barometer with a hobby board barometer
It reads pressure from 28-32 inHg (948-1083 mb). It's resolution is 0.01 inHg (0.34 mb).
01/01/2009
Added a vortex wind speed sensor, and a electronic E-Vane to the 1 wire weather station
05/02/2009
Designed surge protection voltage snap back to protect vortex wind speed sensor, and a electronic E-Vaneon
04/01/2009
designed a surge protection voltage snapback, with LED indicators, fuse protection, for the one wire power injection source
29/03/2009
Data may be missing from this day due to testing wind sensors with the windworks interface
Testing all angles for the compass in weather display data was all correct and there were no dead spots
16/06/2009
Fitted a 1 wire rain gauge sensor
03/12/2009
Checked all wiring, checked all junction boxes, tested devices,
Calibration all temperature sensors
Replacement sensors , temperature, humidity, HB UV { temperature, humidity circuit board may fail ,possible component
failure due to short circuit caused by spider?
HB UV sensor was returned for diagnostics ,temporary using uv1 mod on the Oregon station
01/03/2010
Replaced plastic junction box
With a new type no screws/ locking pegs to secure lid
10/03/2010
Replaced junction box on the screen box
replaced temperature/humidity Sensor
and calibrated
24/03/2010
Installed earthquake sensor
data is on webpage
30/03/2010
Mounted a experimental non-tipping rain gauge
waiting for software to be Compatible with this device
13/04/2010
Replaced fan in screen box